Tech specs
FireProtect 2 AC (CO) Jeweller
Wireless mains-powered fire detector with CO sensor
Devices compatibility
CheckCommunication
Jeweller communication technology
Proprietary wireless communication technology to transmit commands, alarms, and events.
Key features:
- Two-way communication.
- Advanced anti-sabotage.
- Block encryption featuring a dynamic key.
- Instant notifications.
- Remote configuration in the Ajax apps.
Frequency bands
866.0 – 866.5 MHz
868.0 – 868.6 MHz
868.7 – 869.2 MHz
905.0 – 926.5 MHz
915.85 – 926.5 MHz
921.0 – 922.0 MHz
Depends on the region of sale.
Maximum effective radiated power (ERP)
up to 20 mW
Automatic power control to reduce power consumption and noise interference.
Radio signal modulation
GFSK
Radio communication range
up to 4,900 ft
Between detector and hub (or range extender) in an open space.
Encrypted communication
All stored and transmitted data are protected by block encryption featuring a dynamic key.
Frequency hopping
Radio communication uses frequency hopping to prevent interception and jamming.
Carbon monoxide (CO) detection
Sensitive element
chemical CO sensor
Alarm if accumulated dose of CO is exceeded
over 50 ppm (0.005%) — in 90 minutes or less
over 100 ppm (0.01%) — in 40 minutes or less
over 300 ppm (0.03%) — in 3 minutes
CO concentration exceeding 400 ppm (0.04%) within a span of 3 hours poses a life-threatening risk. The detector will cease notifications regarding hazardous carbon monoxide levels once the concentration decreases to 50 ppm (0.005%) within a 1-minute duration.
Sensor service life
10 years
After 10 years of operation, the detector must be replaced with a new one.
Additional features
Built-in siren
volume 85 dB at a distance of 9 ft
Sound notification of alarms. Remains active until the reason for triggering is eliminated or until the user manually disables the notification.
Interconnected fire detectors alarms
via primary interconnection
If one of the fire detectors in the system detects a threat, it sends an alarm to the hub. Within 20 seconds, the hub initiates an interconnected alarm and sends data to Ajax apps.
via fallback interconnection
At the same time with notifying the hub, the initiating detector sends an alarm directly to other detectors. All connected detectors activate the buzzer within a minute. It will work even in the worst-case scenario of losing connection with the hub.
LED indication
green is a power indication
An LED indicator on the device enclosure lights continuously when powered by an external power source. If the device draws power from the backup battery, the LED indicator lights up once every 56 seconds. This indication complies with the requirements stipulated in EN 14604 and EN 50291 standards.
yellow is a malfunction indication
An LED indicator on the device enclosure lights up to signal detected malfunctions. This can occur in instances such as battery depletion, smoke chamber contamination, or reaching the end of the service life.
red is a fire alarm indication
An LED indicator on the device enclosure lights up when the detector registers a fire alarm.
Button on the front panel of the detector
In normal mode, when pressed, it starts the smoke chamber test. In the event of an alarm or malfunction, the pressing turns off the detector sound notification.
External power supply
110–240 V~, 50/60 Hz
The phase and neutral cables from the external power supply should be connected to the WAGO terminals on SmartBracket mounting panel. To remove the detector from SmartBracket, there is no need to disconnect the power cables.
Recommendations
The device is designed for indoor installation only.
SmartBracket mounting panel allows adjusting the position of the detector even after installation.
Sabotage protection
Tamper alarm
Notifications on attempts to detach the detector from the surface or remove it from the mounting panel.
Protection against spoofing
device authentication
Communication loss detection
within 15 minutes
The time required to detect a communication loss depends on the settings for the number of undelivered data packages (specified in the Jeweller or Jeweller/Fibra settings).
Power supply
Main
110–240 V~, 50/60 Hz
Up to 2 W of mains power consumption.
Backup
1 non-replaceable lithium battery CR-2/3AZ
Allows the detector to operate autonomously without the main power source.
Enclosure
Dimensions
4.80″ × 4.80″ × 2.13″
Weight
10.72 oz
Operating temperature range
from 32°F to 122°F
Operating humidity
up to 80%
Colours
Black
White
Complete set
FireProtect 2 AC (CO) Jeweller
SmartBracket mounting panel
WAGO 221 3-conductor terminal — 2 pcs.
(pre-installed in SmartBracket)
Installation kit
Quick start guide
Certification and compliance with standards
FireProtect 2 AC (CO) Jeweller
FireProtect 2 AC (CO) Jeweller
Electrical apparatus for the detection of carbon monoxide in domestic premises
UkrTEST of SE “Ukrmetrteststandart”
EN 50291-1:2018
BS EN 50291-1: 2018
Radio Equipment Directive (RED)
Certificate issued by MiCOM Labs
- EN 300 220-1 V3.1.1
- EN 300 220-2 V3.2.1
Restriction of Hazardous Substances Directive (RoHS)
Shenzhen NTEK Testing Technology Co.
EN IEC 63000:2018
Electromagnetic Compatibility Directive (EMC)
Certificate issued by MiCOM Labs
- EN 301 489-1 V2.2.3
- EN 301 489-3 V2.1.1
- EN 55032:2015+A1:2020
- EN 55035:2017+A11:2020
- EN IEC 61000-3-2:2019+A1:2021
- EN 61000-3-3:2013+A2:2021
Low Voltage Directive (LVD)
Certificate issued by MiCOM Labs
- EN 62479:2010
- EN IEC 62368-1:2020+A11:2020
BSI KITEMARK Carbon Monoxide Alarms
Certificate issued by BSI Assurance UK Ltd.
KM 797661
FCC ID
Certification Issued Under the Authority of the Federal Communications Commission
2AX5VFIACC1
IC ID
Certificate issued by MiCOM Labs
26860-FIACC1
PSTI UK
Schedule 1
CableTrunk
Restriction of Hazardous Substances Directive (RoHS)
EN IEC 63000:2018