Ćōũńţŕŷ:
United States
Ĺàńĝũàĝē:

Partner Portal

Internal battery RB (6.4V/36Ah)

Ũƥďàţēď

Internal battery RB (6.4V/36Ah)

Internal battery RB (6.4V/36Ah) is a rechargeable battery for powering the hub. It consists of a pack of 36 lithium iron phosphate (LiFePO₄) rechargeable cell batteries.

Functional elements

  1. Battery.

  2. Cable.

  3. Connector for attaching the battery to the hub.

Compatible hubs

A compatible Ajax hub is required for the battery to operate.

Check device compatibility

Operating principle

Internal battery RB (6.4V/36Ah) is an internal rechargeable battery used to power the hub. It can power the hub both independently and as a backup power source when an external battery is used.

Selecting an installation site

When choosing the battery location, consider the factors that affect its operation:

  • Operating temperature range.

  • Permissible humidity level.

Consider the placement recommendations when designing your Ajax system. The security system must be designed and installed by specialists. The list of recommended Ajax partners is available here.

Where not to install the battery

  1. In places with high temperature — for example, near heat sources, such as radiators, heaters, direct sunlight, etc. High temperature can cause battery overheating, rapid self-discharge, damage to its components, explosion, or fire.

  2. In places with high humidity. Moisture can corrode the contacts or cause a short circuit.

  3. Near flammable materials. Never place the battery near flammable liquids or materials. Doing so increases the risk of fire or explosion, especially if a short circuit occurs.

Preparing for installation

Before installing Internal battery RB (6.4V/36Ah), ensure it is compatible with the hub. Also, read this manual and the hub user guide.

Avoid deviations from the system project. Violating the basic installation rules and the recommendations of this manual may cause the device to operate incorrectly.

Cable arrangement

When preparing for cable routing, read and strictly follow the electrical and fire safety regulations in your area.

Installation and configuration

Before installation, ensure that you have selected the optimal device location that meets the requirements of this manual.

Installing the battery in the casing

  1. Remove the front panel of the hub casing.

  2. Turn off the hub.

  3. Locate the internal battery connector on the board (Internal supply).

  4. Connect the battery to the board connector.

  5. Secure the battery in the casing with ties. Do not tighten the ties too much to avoid damaging the board and cell contacts inside the battery.

  6. Turn on the hub.

  7. Close the hub casing.

  8. Select the battery type in the hub settings.

  9. Check the battery connection state in an Ajax app.

Configuring the battery

After installing the battery, select the correct hub settings in the Ajax PRO app.

  1. Select the required space or object.

  2. Go to the Devices HubFilled-M tab.

  3. Select the hub from the list.

  4. Go to its Settings Settings-M.

  5. Go to the Service menu.

  6. Go to the Battery settings menu.

  7. Select the Rechargeable lithium battery option for the Internal battery type setting.

  8. Configure other battery settings if necessary.

  9. Tap Back to save the settings.

States

The hub states include information about the battery connection status. They can be found in Ajax apps:

  1. Go to the Devices HubFilled-M tab.

  2. Select the hub from the list.

Maintenance

Internal battery RB (6.4V/36Ah) is rechargeable and maintenance-free.

Recommended battery chargers

Before using the battery charger, carefully read the manufacturer’s instructions. They contain guidance on safe use and recommended parameters.

The complete set includes the cable adapter for connecting the battery to the charger.

List of recommended battery chargers for Internal battery RB (6.4V/36Ah)

Manufacturer

Model

Full battery charge time

Notes

SkyRC

Ultimate Duo 400W

11 hours

Supports simultaneous charging of two batteries.

SkyRC

iMAX B6mini

11 hours

SkyRC

iMAX B6AC V2

11 hours

ToolkitRC

M6DAC

11 hours

Supports simultaneous charging of two batteries.

HTRC

T240 DUO

11 hours

EV-PEAK

C1-XR

11 hours

Hitec

RDX1 Mini

11 hours

Charging profile and recommended parameters for the battery charger

Parameter

Value

Battery type

LiFe

Charging current

4 A

TVC (Terminal Voltage Control)

7.2 V

Temperature cutoff

+45 °C / 113 °F

Cell configuration

2S

Capacity cutoff

Off

Safety timer

720 minutes

Storage conditions

The battery should be stored in a cool, dry, and well-ventilated place at a temperature not exceeding 86 °F. The battery should be charged to about 30–50% of its capacity. These conditions are necessary to reduce battery degradation.

It is recommended that the battery be charged once every six months to prevent overdischarge.

Technical specifications

All technical specifications

Compliance with standards

Contacting technical support

If the device does not operate properly, we recommend contacting Ajax technical support first. In most cases, technical issues can be resolved remotely.

Ńēēď ĥēĺƥ?

Ĩń ţĥĩś śēćţĩōń ŷōũ'ĺĺ ƒĩńď ďēţàĩĺēď ḿàńũàĺś àńď ēďũćàţĩōńàĺ vĩďēōś àƀōũţ àĺĺ ƒēàţũŕēś ōƒ ÀĴàx. Àńď ĩń ćàśē ŷōũ ńēēď ĥēĺƥ ōƒ à ţēćĥńĩćàĺ śƥēćĩàĺĩśţ, ŵē'ŕē àvàĩĺàƀĺē 24/7.

Śēńď ŕēǫũēśţ
Ajax Systems