Language:

Partner Portal

Tech specs

Type4 Fire Hub Jeweller

Wireless Type 4 addressable fire alarm central unit with a touch screen

Type4 Fire Hub Jeweller

Device compatibility

Capacity

Devices

up to 200

Supports Ajax devices only from the Type4 product line in any combination. Up to 5 Type4 Fire ReX Jeweller range extenders can be added.

Fire zones

up to 40

Alerts about fire in separate zones. Every zone may include multiple rooms.

Users

up to 200

  • Any number of admin users within the fire alarm central unit limit.
  • PRO accounts for installers.
  • PRO accounts for installation and monitoring companies.
  • Access management for users.

Automation scenarios

up to 64

  • By alarm.
  • By schedule.
  • By arming/disarming.

Rooms

up to 80

Security groups

up to 25

Event log

up to 5,000 events

Fire alarm system events. Can be viewed on the Type4 Fire Hub Jeweller display. Events are saved on the non-volatile onboard flash memory.

up to 500 events

Can be viewed in the events feed in Ajax apps.

Communication

Jeweller communication technology

Proprietary wireless communication technology to transmit commands, alarms, and events.

Key features:

  • Two-way communication.
  • Advanced sabotage protection.
  • Block encryption featuring a dynamic key.
  • Instant notifications.
  • Remote control and configuration in Ajax apps.

Frequency bands

868.0–868.6 MHz

Maximum effective radiated power (ERP)

up to 20 mW

Automatic power control to reduce power consumption and radio interference.

Radio signal modulation

GFSK

Radio communication range

up to 1,800 m

Between the fire alarm central unit and connected devices (in an open space).

Maximum range depends on the connected device.

Encrypted communication

All stored and transmitted data are protected by block encryption featuring a dynamic key.

Frequency hopping

To prevent radio interference and jamming.

Wings communication technology

Proprietary wireless communication technology to update firmware.

Key features:

  • Two-way communication.
  • Advanced sabotage protection.
  • Block encryption featuring a dynamic key.
  • Data packages reload in case of transmission errors.

Frequency bands

868.0–868.6 MHz

Depends on the sales region.

Radio communication range

up to 1,800 m

Between the fire alarm central unit and connected devices (in an open space).

Maximum range depends on the connected device.

Encrypted communication

All stored and transmitted data is protected by block encryption featuring a dynamic key.

Frequency hopping

To prevent radio interference and jamming.

Communication channels

Ethernet

1 8P8C socket

Up to 100 Mbps.

Cellular

2 micro-SIM slots

Cellular frequencies

2G

GSM900/DCS1800 (B3/B8)

4G (LTE)

FDD B1/B3/B5/B7/B8/B20

Wi-Fi

802.11 b/g/n module

up to 72 Mbps.

Automatic switching between communication channels

  • Instant switching between Ethernet, Wi-Fi, and SIM.
  • Instant switching between 4G (LTE), 3G, and 2G networks of one SIM.
  • Switching between SIMs takes up to 4 minutes.

Communication channels prioritization

  1. Ethernet
  2. Wi-Fi
  3. Cellular connection

Communication channels work in parallel to increase the system’s reliability. Most of the data is transmitted via Ethernet.

Ethernet
Cellular

Notifications

Supported notification types

  • Push notifications
  • SMS
  • Calls

Event types

  • Alarms
  • Video alerts
  • Faults
  • Security state change
  • System events
  • Non-security alerts
  • Doorbell ringing

The notification types are configured individually for each user.

Supported notification types

Monitoring

Supported protocols

  • SIA (DC-09)
  • SurGard (Contact ID)

Event types

  • System alarms and events
  • Panic button coordinates

Fire alarm system management

Indication of fire alarms and faults

  • display
  • LED indicators
  • sound

LEDs on the front panel of the fire alarm central unit and the built-in buzzer notify users of fire alarms in zones, faults, and system states. In case of fire, the fire alarm central unit also activates visual alarm devices and fire alarm sounders. The Type4 Fire Hub Jeweller display also shows system states and detailed alarm information.

Fire alarm control

  • start evacuation
  • stop evacuation (available for manually started evacuation)
  • indication test

Users with appropriate rights can manage the fire alarm system via these options.

Fire alarm system settings

Users with appropriate rights can configure all fire alarm system settings via the fire alarm central unit.

Event log

Stores a detailed log of fire alarms and system events. Capacity: up to 5,000 events.

Additional features

User authorization

To manage the fire alarm system via the Type4 Fire Hub Jeweller touch screen, the user must log in by entering a code or presenting a personal access device.

Control

Access codes

up to 200 codes

One code per each user. Defines user access level to security and fire alarm system management.

Built-in buzzer

volume at least 60 dB at a distance of 1 m

Sound alerts of fire alarms.

volume at least 50 dB at a distance of 1 m

Sound alerts of faults.

LED indication

red

For fire alarms.

yellow

For device faults, tests, and disablements.

green

For power supply status.

LED indication

Special tool (key)

The special tool is used to unlock the housing and replace the internal battery or dismantle the device from the SmartBracket mounting panel. The battery is not included in the Type4 Fire Hub Jeweller complete set.

Special tool (key)
Special tool (key)

Display

Diagonal

10.1″

Matrix type

IPS

Resolution

1024 × 600 px

Sensor

capacitive

Backlight settings

Manually adjustable in the Type4 Fire Hub Jeweller on-screen settings.

Interface language

Configurable via the fire alarm central unit touch screen or in the Type4 Fire Hub Jeweller settings in Ajax apps.

Outputs

Output 1

Relay output for alerting the monitoring company in case of a system fault. Contact state is normally closed (NC) by default.

Output 2

Relay output for alerting the monitoring company in case of a fire alarm. Contact state is normally open (NO) by default.

Operating mode

bistable

External power supply

10–30 V⎓

The relay does not supply power to connected devices.

Energy consumption

up to 60 W

In standby mode.

Maximum resistive load

up to 2 A at 30 V⎓

Maximum inductive/capacitive load

up to 2 A at 30 V⎓

Installation recommendations

The device is designed for indoor use only.

Use GlandBox if power and signal cables are not routed inside the wall.

The device operating voltage is 110–240 V~.

Sabotage protection

Tamper button

Notifications about the fault on attempts to detach the device from the surface or remove the mounting panel.

Protection against spoofing

device authentication

Connection loss detection

after 36 s

Detection time depends on Jeweller settings.

Power supply

External

110–240 V, 50/60 Hz

Up to 0.48 A of mains power consumption.

Internal

7.4 V⎓, 5 Ah/10 Ah

On Rechargeable Li-ion battery not included in the complete set: Type4 Internal Battery (24h) or Type4 Internal Battery (72h).

Autonomous operation

On internal battery

up to 24 hours

On Type4 Internal Battery (24h) not included in the complete set. Battery life is based on display activation only when tapped, using W-Fi, Ethernet, and cellular (LTE) communication channels.

up to 72 hours

On Type4 Internal Battery (72h) not included in the complete set. Battery life is based on display activation only when tapped, using W-Fi, Ethernet, and cellular (LTE) communication channels.

Enclosure

Dimensions

263 × 223 × 54 mm

Weight

1,526 g

Operating temperature range

from -10 °C to +40 °C

Operating humidity

up to 75% non-condensing

Protection class

IP20

Flammability rating

UL 94 V-0

Dimensions
Dimensions

Color

Black

Black

White

White

Complete set

Type4 Fire Hub Jeweller

SmartBracket mounting panel

Installation kit

Ethernet cable

Special tool (key)

Quick start guide

Revision

1

Additional information

Compliance with standards

Learn more

Warranty

24 months

Learn more