Language:

Partner Portal

FireProtect 2 (Heat/Smoke/CO) Jeweller

FireProtect 2 (Heat/Smoke/CO) Jeweller

Wireless fire detector with heat, smoke, and CO sensors

Product versions

FireProtect 2 RB (Heat/Smoke) Jeweller

FireProtect 2 RB (Heat/Smoke/CO) Jeweller

Up to 7 years of operation on replaceable batteries

FireProtect 2 SB (Heat/Smoke) Jeweller

FireProtect 2 SB (Heat/Smoke/CO) Jeweller

Up to 10 years of operation on sealed batteries

Accuracy through steam, dust, and time

FireProtect 2 (Heat/Smoke/CO) Jeweller is a battery-powered fire detector designed to protect homes without false alarms. Its dustproof and insect-resistant smoke chamber, dual-spectrum optical sensor, proprietary software algorithm, two thermistors, and a chemical carbon monoxide (CO) sensor deliver best-in-class detection accuracy. If danger is real, an 85 dB siren, two interconnection types, and instant push notifications in Ajax apps make the alarm impossible to ignore. With thoughtful design, self-monitoring, and early low battery alerts, the device ensures uninterrupted protection with fewer maintenance visits.

FireProtect 2 Jeweller features in two minutes

Wireless fire detector with heat, smoke, and/or CO sensors

Watch on Youtube

Discover Ajax fire and life safety category

Watch Ajax Special Event to learn what makes Ajax fire and life safety category unique

Watch on Youtube

Key features

Two types of interconnected fire alarm

Interconnected fire alarm

Primary: via an Ajax hub, alarm within 20 s

Versions with different battery types

Replaceable

Sealed

Sensors

Heat

smoke-sensor-s

Smoke

CO

Remote control

Remote control and configuration

85 dB built-in siren

85 dB built-in siren

Compliance with standards

Informative push notifications

Ajax logo
10:00

Ajax

Home: signs of smoke detected, FireProtect 2 in Kitchen

Ajax logo
10:00

Ajax

Home: received photo by scenario Smoke in the kitchen, MotionCam (PhOD) in Kitchen

Up to 5,550 ft

Communication range with an Ajax hub in open space

Jeweller radio communication

Jeweller radio communication

Power adjustment

Two colors

Two colors

Hassle-free installation

1

QR-code

2

SmartBracket

3

App

Operates as part of the Ajax system or as a standalone device

Smartbracket

SmartBracket

with an adjustable rotation angle

Dual-spectrum optical smoke sensor

to filter out false alarms

Dual-spectrum optical smoke sensor
Dustproof and insect-resistant smoke chamber

Dustproof and insect-resistant smoke chamber

Device compatibility

Awards

Test Winner
Readers' choice awards
PSI 2025

Wherever there is a risk of fire

Kitchen

Kitchen

Living room

Living room

Bedroom

Bedroom

Hall

Hall

Home office

Home office

Pantry

Pantry

Basement

Basement

Barn

Barn

Workshop

Workshop

Discover future-proof hardware

Smoke chamber with a dual-spectrum optical sensor

Smoke chamber with a dual-spectrum optical sensor

Two thermistors

Two thermistors

Chemical CO sensor

Chemical CO sensor

Test/Mute mechanical button

Test/Mute mechanical button

LED indication of detector states

LED indication of detector states

Batteries

Batteries

85 dB siren

85 dB siren

SmartBracket mounting panel

SmartBracket mounting panel

Detection without compromise

Smoke detection

The detector is designed to ensure accurate smoke detection over time. A dustproof and insect-resistant smoke chamber features a dual-spectrum optical sensor. It uses blue and infrared LEDs to measure the concentration of combustion products and the size of their volatile particles. The HazeFlow 2 algorithm then analyzes the collected data to distinguish smoke from false triggers, such as vapor or steam. If the analysis indicates a real fire, the detector instantly raises an alarm.

Smoke detection

Heat detection

FireProtect 2 (Heat/Smoke/CO) Jeweller is equipped with two A1R-class thermistors to detect smokeless fires. Positioned outside the enclosure, the thermistors immediately register if the temperature rises by 50 °F within a minute or exceeds a threshold of 147 °F. This design ensures the fastest possible response, even when a threat grows gradually.

Heat detection

CO detection

CO is a highly poisonous yet colorless and odorless gas. Without a CO detector, it can build up unnoticed until poisoning occurs. Equipped with a chemical sensor, FireProtect 2 (Heat/Smoke/CO) Jeweller monitors the CO level and warns about dangerous concentrations before the first symptoms appear. The sensor ensures reliable CO detection for up to 10 years.

The detector is triggered if the CO level reaches:

  • 50 ppm in no more than 90 minutes
  • 100 ppm in no more than 40 minutes
  • 300 ppm in no more than 3 minutes
CO detection

Stable performance for a decade

FireProtect 2 (Heat/Smoke/CO) Jeweller delivers up to 10 years of autonomous operation thanks to pre-installed batteries, sealed or replaceable. Real-time battery status is always visible in Ajax apps, so there is no need for unnecessary maintenance visits. If the battery runs low, users receive push notifications and on-site LED and sound alerts 30 days before the full discharge.

SB version

SB version

Up to 10 years of operation

on sealed batteries

RB version

RB version

Up to 7 years of operation

on replaceable CR123A batteries

Clear alerts for faster response

In addition to LED indication, FireProtect 2 (Heat/Smoke/CO) Jeweller features impossible-to-ignore sound alerts, thanks to a powerful 85 dB siren with distinct tones. Each indication corresponds to a specific event, drawing attention and helping users react accordingly.

Sound and LED indications

Smoke or heat alarms

Dangerous CO level

Malfunction

Low battery

End of life

Sound and LED indications

Enhanced wireless interconnection

To spread an alarm across the facility as quickly as possible, FireProtect 2 (Heat/Smoke/CO) Jeweller supports primary and fallback1 interconnection with other on-site fire detectors. The primary one operates via a hub: the detectors alert the hub to a threat, which then activates the sirens of all fire detectors on-site. The process takes just 20 seconds — three times faster than standards require. If hub communication is lost, the fallback interconnection takes over. The initiating fire detector directly communicates with other devices, raising the alarm across the system within a minute. Even in the worst-case scenario, people on-site are warned and have time to act.

Primary interconnection via a hub

20 seconds to activate up to 200 fire detectors

Fallback interconnection

60 seconds to activate up to 50 fire detectors

Advanced automation for greater safety

While FireProtect 2 Jeweller detectors can be used as standalone devices, they gain many more capabilities within a larger Ajax system. They can interact with automation devices and MotionCam (PhOD) Jeweller detectors via scenarios, triggering automated responses to fire alarms. This interaction helps enhance home protection when people are away or speed up evacuation when they are on site.

To quickly assess the situation at the protected facility and respond accordingly.

Photo evidence of fire

Fire detected

FireProtect 2 Jeweller

MotionCam (PhOD) Jeweller

Cause of fire

To cut off power to a possible source of fire and protect appliances from the consequences of firefighting.

Power supply control

Fire detected

FireProtect 2 Jeweller

WallSwitch Jeweller

Mains power cut

Relay Jeweller

Emergency lights activated

To supply fresh air and reduce carbon monoxide concentration in the air.

Ventilation system control

CO detected

FireProtect 2 Jeweller

WallSwitch Jeweller

Ventilation on

To speed up people's evacuation and ease firefighters' access to the building.

Electric locks unlocking

Fire detected

FireProtect 2 Jeweller

Relay Jeweller

Emergency exits unlocked

Unique wireless technology

Unique wireless technology

Jeweller is Ajax’s proprietary radio protocol for secure two-way communication. It provides block encryption and device authentication during each communication session with an Ajax hub or radio signal range extender. Jeweller prevents sabotage, spoofing, and data theft.

Up to 5,550 ft of communication range in an open space

Data encryption

Notification of jamming and connection loss

Automatic power adjustment

Effortless installation and maintenance

FireProtect 2 (Heat/Smoke/CO) Jeweller is ready to operate straight out of the box. With no enclosure disassembly required and intuitive in-app setup, it can be up and running within minutes. Maintenance and testing are just as effortless thanks to the self-test feature, real-time device state, and remote configuration available in Ajax apps.

Adding to the system via a QR code

Connection

SmartBracket panel with a 90° rotation angle and no enclosure disassembly

Installation

Configuration and testing in mobile and desktop Ajax apps

Setup

Dustproof and insect-resistant smoke chamber that does not require cleaning

Maintenance
1

Fallback interconnection is available only for FireProtect 2 Jeweller detectors with firmware version 5.59.2.9 or later.

Technical information

FireProtect 2 RB (Heat/Smoke/CO) Jeweller

FireProtect 2 SB (Heat/Smoke/CO) Jeweller

Ajax product categories

In an Ajax system, you can combine devices of all product categories: Intrusion protection, Video surveillance, Fire and life safety, or Comfort and automation. Create the system to suit your needs and manage it in a single interface.

Fire sensors of the security system

Fire alarm system designed to detect fires, points in the room with high air temperature and smoke. These measures include an alarm system, fire suppression, smoke extraction, shut-off of supply ventilation and air conditioning to stop the spread of fire in the event of an emergency.

What are the components of a fire alarm system

Fire alarm systems include sensors, receiving and control equipment, warning systems, communication channels, backup power supply, special software and other elements.

Fire sensors are divided into four main types:

1) The heat sensor of the fire alarm system reacts to the presence of temperature changes. Heat sensors are divided into:

  • a) threshold - with a given limit of a certain temperature level, after which the sensors will be triggered.
  • b) integral — respond to a rapid temperature increase. Due to the temperature threshold at which the sensor is activated, which is approximately 70 °C, threshold fire sensors have relatively low efficiency. The low cost of these sensors is the only factor affecting demand. Fires at an early stage can be detected with the help of built-in fire detectors. However, due to the fact that they use two thermocouples, one outside the sensor and the other inside, and the signal processing system is built into the sensor itself, the cost of such fire detectors will be high.

Only when heat is the primary symptom of a fire can heat sensors be used for fire alarms.2) Smoke detectors. Smoke in the air is detected by smoke detectors. The theory of scattering of infrared radiation on smoke particles is the basis of the operation of almost all types of smoke detectors. The disadvantage of such a sensor is that it can work in environments with high levels of steam or dust. Although it is obviously not used in dusty or smoky environments, the smoke detector is used quite often.3) The flame sensor indicates the presence of an open fire or smoldering fireplace. Flame detectors must be installed in places where a fire can start without the prior release of smoke. Because flame detection occurs at an early stage, when conditions such as smoke and a significant increase of temperature are absent, they are more effective than the previous two types of detectors. In addition, in some industrial buildings, which are characterized by high dustiness or significant heat exchange, only fire detectors are used.4) Combined fire alarm sensors combine different fire indication identification methods. Most often, combined sensors combine a heat detector with a smoke detector. This makes it possible to more accurately determine the presence of a fire indication so that an alarm signal can be sent to the remote control. The complexity of the technologies used to create these sensors affects their cost.A correctly constructed fire alarm system, which depends on the information from the fire detector, is directly responsible for the entire effectiveness of the fire extinguishing system. Thanks to this, you can evaluate the effectiveness of the fire protection system of the building as a whole, taking into account the optimal location, the use of the appropriate type of sensor for certain rooms and the quality of fire detectors.In the event of a fire, notification systems for residents, guests, or personnel of buildings and structures contribute to the prompt evacuation of people. Using the Ajax sensor as an example, we will show the principle of operation and features of combined fire sensors.

FireProtect 2 (Heat/Smoke/CO) — a wireless fire detector with smoke, temperature and carbon monoxide sensors

The FireProtect 2 (Heat/Smoke/CO) wireless fire detector is designed for quick fire detection. A dual-spectrum sensor can distinguish between smoke and water vapor. The thermistor quickly reacts to the burning of synthetic materials. The one-of-a-kind smoke chamber does not require frequent cleaning, and simple software reduces false alarms. All this complies with the latest fire safety regulations. The well-thought-out mounting and design of the sensor, as well as the settings via smartphone, ensure easy and quick installation of the fire sensor. A built-in siren for alarm and event notification is included in the fire detector. The FireProtect 2 (Heat/Smoke/CO) wireless fire detector can function both independently and as part of the Ajax security system.

The sensor is available in two versions. Model with replaceable batteries and non-replaceable - RB and SB, respectively.

The principle of operation of the Ajax FireProtect 2 (Heat/Smoke/CO) wireless fire detector

Detecting smoke and not ignoring water vapor with the fire detector Ajax FireProtect 2 is possible thanks to a bispectral optical sensor with blue and infrared LEDs. LEDs emit light with different wavelengths. This allows the device to determine the size of the volatile particles and react to the smoke.The smoke chamber of the sensor is protected from external debris and insects. Dust does not threaten detection and does not damage the device, even if it enters and settles in the smoke chamber. Air particles or insects cannot be in two beams at the same time and cause an alarm due to the structure of the optical system.Two built-in thermistors are responsible for the response to the increase in temperature of the wireless fire detector. Thermistors are located outside the sensor for better threat detection. The sensor detects rapid temperature rise and sounds an alarm if the room temperature exceeds 64 °C or rises by 10 °C or more within one minute, even in the absence of smoke. In FireProtect 2 (Heat/Smoke/CO), a built-in chemical sensor with a service life of at least 10 years is responsible for detecting a dangerous concentration of carbon monoxide.Carbon monoxide (CO) is a colorless, tasteless, and odorless gas produced when the fuel in heating engines and vehicle engines that use coal or other natural fuels does not burn completely. For example, it can be created through heating systems, boilers or fireplaces. In closed, sealed rooms with insufficient ventilation, life-threatening concentrations of carbon monoxide can accumulate.The interconnected fire alarm fire alarm function activates the built-in sirens of all Ajax fire detectors in the system if at least one of them has responded to the trigger. This makes it possible to notify as many people as possible inside the building in the event of a fire.

The sirens of all FireProtect 2 (Heat/Smoke/CO) sensors can be activated in 20 seconds thanks to the advanced algorithm of the synchronized alarm.

FireProtect 2 (Heat/Smoke/CO) sensors can be used without connecting to an Ajax control panel. In this case, the sensor notifies of fire alarms with a built-in siren and LED indication, but does not send a notification to the user's smartphone, Ajax Translator or the PRO Desktop application.

Jeweller wireless communication technology

A radio protocol called Jeweller provides fast and reliable two-way communication between connected devices and the hub of the security system. The protocol allows wireless connection of the control panel with FireProtect 2 (Heat/Smoke/CO) at a distance of up to 1700 meters. Even on very large objects, sensors can be installed thanks to such a communication range. In a system with any number of FireProtect 2 (Heat/Smoke/CO), the radio protocol also allows for a synchronized alarm of fire detectors to be triggered in 20 seconds. Thanks to Jeweller, users and the monitoring panel can always view the current status of detectors in Ajax applications.The wireless fire detector Ajax FireProtect 2 (Heat/Smoke/CO) constantly checks the state of the battery and built-in sensors. If a fault is detected, the hub will immediately notify users and the monitoring console. And the sensor will turn on the built-in siren and LEDs for light and sound alarm notification, respectively. In Ajax applications, all sensor states can be checked at any time.The sensor can be tested manually. When you press the front panel of the sensor, it turns on. The mechanical button on the front panel can be pressed both by hand and, for example, with a mop. During the test, the built-in siren is activated, and the sensors are checked. This allows the installation engineer to test the device when necessary and show the customer how the sensor will react to different types of alarms with sound and light.

Autonomous operation of the FireProtect 2 (Heat/Smoke/CO) wireless fire detector

The FireProtect 2 (Heat, Smoke, CO) fire alarm sensor is available in two models with replaceable and fixed power cells. Sensors with replaceable batteries can last up to 7 years with CR123A batteries already installed. Discharged batteries can be replaced with new ones.The permanent battery model uses built-in lithium power cells for at least 10 years of operation. Such a sensor must be replaced with a new one after the batteries are discharged.

Installation and connection of the Ajax FireProtect 2 (Heat/Smoke/CO) wireless fire detector

It is not necessary to open the sensor enclosure to install FireProtect 2. Pre-installed replaceable or fixed power supplies are available, and no tools are required to remove the SmartBracket from the sensor. The SmartBracket mounting panel allows you to later align the position of the sensor after installation.In less than a minute, the sensor is connected to the Ajax security system. You need to run the Ajax app, scan the QR code and add the device to the security group and room.